Abstract: In recent years the city center area commercial real estate development of many commercial building, the lower part of the large space commercial buildings, the upper part of the main building of irregular small bay business office, or apartment building, the upper and lower part of the vertical column wall structure due to not in the same verticalforce transformation and the need to position the design to produce a large volume of transfer beam and span of the office lobby, conference rooms, etc., while high steel tubular support frame erection difficulties and focus the beam with the span. In this paper, project examples for analysis of the support frame construction.

Keywords: tall formwork support shelf, load.

中图分类号:[TU208.3]文献标识码:A 文章编号:

一、工程概况

兴义金州国际居住小区A栋,共18层,层高3米。剪力墙结构。1—10层为两栋独立建筑,分别位于建筑平面的1—9轴线及19—27轴线。在十一层(29.95米)9—19轴(轴线跨度17.4米)设转换梁抬此部分上部8层。梁截面分别为1200×2500,1200×2200,850×1000,800×1000,700×1000。

混凝土采用商品混凝土泵送施工,本文以高大支模施工为例分析该支撑架施工技术。

二、支撑架方案设计

在选择方案时,模板及其支架的结构设计,力求做到结构要安全可靠,造价经济合理并结综合考虑了以往的施工经验,采用钢管支撑架模板施工方案;

2.1转换层结构施工荷载计算(荷载取值详DB33/1035-2006)

(1)、模板的自重按:0.35KN/m

(2)、施工人员及设备荷载标准值按:3KN/m

(3)、振捣混凝土时产生的荷载标准值按:2KN/m

(4)、混泥土自重:24×1.05×1=25.2KN/M

(5)钢筋及型钢自重:7.04×1/1.2=5.87KN/M

木工板的材料参数:弹性模量E=9500N/mm²,抗弯设计值【σ】=13N/mm²,截面模量W=1000×18×18/6=5.4×104mm³,惯性矩I=1000×18×18×18/12=4.86×105mm4.

2.2以最大截面尺寸构件梁进行验算:

底模荷载标准值q1=25.2+5.87+0.35+3+2=36.42KN/M

设计值q2=1.2×(25.2+5.87+0.35)+1.4×(3+2)=44.7KN/M

底模按连续三跨计算,抗弯强度验算:

最大弯矩M=0.1ql=0.1×44.7×0.2×0.2=0.18KM.M

弯曲应力σ=M/W=0.18×106/5.4×104=3.33N/m㎡<13(满足)

扰度验算:A=0.667q1L4/100EI=0.08<L150(满足)

2.3 木枋验算

木枋材料参数:弹性模量10000N/mm2,抗弯设计值(σ)=13N/mm2,抗剪强度设计值【τ】=1.7N/mm2,截面模量W=50×100×100/6=83333.3mm3,惯性矩I=50×100×100×100/12=4.167×104

1)混凝土自重:24×0.2×1.05=5.04KN/M

2)模板自重:0.35×0.2=0.07KN/M

3)施工及设备荷载:3×0.2=0.6KN/M

4)振捣荷载:2.0×0.2=0.4KN/M

5)钢筋自重:7.04×0.2=1.41KN/M

作用于木枋的荷载

设计值q=1.2×(5.04+1.41+0.07)+1.4×(0.6+0.4)=9.22kn/m

标准值q1=5.04+1.41+0.07+0.6+0.4=7.52kn/m

木枋按三联跨连续梁计算,

1、 抗弯验算:

最大弯矩M=0.1ql2=0.1×9.22×0.6×0.6=0.33km.m

弯曲应力σ=M/W=0.33×106/83333.3=3.96mm2〈[σ]=13(满足)

2、抗剪强度验算:

最大剪力:V=0.6ql=0.6×9.22×0.6=3.32kn

最大剪应力:τ=3V/2bh.32×103/2×50×100=1.0N/mm2<[τ]=1.7N/mm2(满足)

3、扰度验算

A=0.667ql4/100EI=(0.667×7.52×6004)/100×10000×4.167×106=0.16mm<L/150(满足要求)

2.4外枋计算

1)混凝土自重:24×0.2×1.05=5.04KN/M

2)模板自重:0.35×(2.5×2+1.2)×0.2=0.43KN/M

3)施工及设备荷载:3×0.2=0.6KN/M

4)振捣荷载:2.0×0.2=0.4KN/M

5)钢筋及型钢自重:7.04×0.2=1.41KN/M

1、枋的荷载

设计值P=1.2×(5.04+1.41+0.43)×0.6+1.4×(0.6+0.4)×0.6=5.79KN

标准值P1=(5.04+1.41+0.43)×0.6+(0.6+0.4)×0.6=4.73KN/M

2、扣件抗滑验算

支座反力R=1.19×2×5.79=13.78采用双扣件,且顶端采用顶托支撑。

2.5立杆稳定性验算

钢管的材料参数:弹性模量E=2.06×105N/mm²,抗弯设计值【σ】=205N/mm²,截面模量W=5080mm³,惯性矩I=12.19×104mm4.

1)立杆水平杆自重:

(30×1.2+30)×38.4+60×14.6+15×18.4=3686N

2)剪刀撑荷载:3.6×3.6米的计算单元核算剪刀撑用钢管1244米,扣件1280个,则每根立杆分担剪刀撑荷载1356N.则钢管自重为5.04KN.

作用于梁底中立杆的荷载N=1.2×5.04+13.78+5.79=25.618KN